TA的每日心情 | 奋斗 半小时前 |
---|
签到天数: 3413 天 连续签到: 15 天 [LV.Master]2000FPS
|
楼主 |
发表于 2024-11-30 17:00:26
|
显示全部楼层
|阅读模式
来自:广东省东莞市 电信
注册登陆后可查看附件和大图,以及购买相关内容
您需要 登录 才可以下载或查看,没有账号?注册会员
x
宝视纳Basler-blaze pylon补充软件包 1.6.0 - Linux ARM 64位 - Debian安装软件包~pylon-supplementary-package-for-blaze-1.6.0.b542964d0_arm64.deb
pylon Supplementary Package for ToF Camera / blaze 1.6.0
2023年9月
1.6.0
Compatible with: pylon 6.2.0, 6.3.0, 7.0.0, 7.2.1, 7.3.0, 7.4.0
在此处下载blaze pylon补充软件包,轻松设置和配置Basler blaze 3D相机。这个软件包包含blaze Viewer,以作为配置和可视化工具。
安装要求
blaze pylon补充软件包需要安装pylon相机软件套装6.2.0或更高版本。
blaze pylon补充软件包 1.6.0 - Linux ARM 64位 - Debian安装软件包
文件名: pylon-supplementary-package-for-blaze-1.6.0.b542964d0_arm64.deb
文件大小: 82949124 字节 (79.11 MB)
修改日期: 2024-10-24 17:52
MD5: 5a725c6590230f6d4786c7ed84529c90
SHA1: b2610346f366e8fbbc259e74e7c59f61d4faa3c2
SHA256: 438974fb197770dd243fe8929448de099e16fa95ea9b14a92caff24cf4d8fc17
CRC32: c2c18b04
Basler官方下载:
百度网盘下载:
链接:https://pan.baidu.com/s/1XLMNE1Rcw9fD8fpp0No-_A
提取码:
RELEASE NOTES
==============
pylon Supplementary Package for blaze
Version: 1.6.0
Release date: 2024-05-03
Preceding release: 1.5.0
Products affected: blaze-101 (order number 107796), revisions 03 or above
blaze-102 (order number 108711)
NEW FEATURES
------------
* Improved handling of the GigE Vision heartbeat timeout. In case an application
has been started under the control of a debugger, the connection to the camera
is closed automatically when the application is terminated or crashes. This
allows you to use the GigE camera again immediately after restarting the
application. pylon 7.1 or above is required for the improved heartbeat timeout
becoming effective.
CHANGES
--------
* Updated OpenCV and Point Cloud Library installation topics in the blaze
C++ Programmer's Guide.
* Fixed an issue causing the producer to not acquire images when the Extended ID
feature is enabled (under Windows with pylon GigE Vision Performance Driver).
Note that the pylon GigE Vision Performance Driver has been discontinued.
You should use the pylon GigE Vision Filter Driver instead.
* Fixed an issue causing the blaze Viewer to crash when the content of the
feature tree search box was deleted.
* Fixed an issue causing the frame ID to only go up to 65535 when the Extended ID
feature was enabled and then to overflow (under Windows with pylon GigE Vision
Filter Driver).
* Fixed an issue where the Gamma Correction feature didn't work properly when
using camera firmware version 4.x.
* Fixed the return type of GetBufferPartInfo BUFFER_PART_INFO_DATA_TYPE
from int to size_t.
* Added the AutoPacketSize and UseExtendedIdWhenSupported parameters. Usage of
GigE Vision Extended IDs is enabled by default.
KNOWN LIMITATIONS
------------------
Windows, pylon versions below pylon 7.2.1:
- Basler generally recommends using pylon 7.3 or above with blaze cameras.
Linux:
- Programming samples using the Point Cloud Library (PCL) may crash depending
on the versions of the PCL and VTK libraries installed on your system. The
crash is due to a bug in the VTK libraries that are used by PCL for 3D
visualization.
Source: https://github.com/PointCloudLibrary/pcl/issues/5237
For example, Ubuntu 22.04 ships versions of the libraries showing the problem.
Solution: PCL 1.13.1 and above contain fixes to work around the VTK bug.
Uninstall the PCL libraries provided by your Linux distribution and build PCL
version 1.13.1 or above from sources (these are available on
https://github.com/PointCloudLibrary/pcl). |
|